How PPM Oil in Water is Measured
Enlarge diagram
.




ISO 9001-2000

 

OIL AND WATER


Oil IN Water refers to products measuring the concentration (in ppm or %) of oil dissolved or emulsified oil in water.

Oil
ON Water refers to products monitoring separated oil on the water surface.

The following products are available through this page. Scroll down below this chart for a quick review of each or click directly on the product for the available documents.

NEW! Quick learning videos
See links below

MODEL FUNCTION DESCRIPTION TECHNOLOGY
HydroSense 2410    . ppm Oil in Water on-line industrial fluorescence
Hydrosense 3410 ppm Oil in Water on-line clean water fluorescence
Hydrosense 3420 ppm Oil in Water on-line clean water light Scatter
FluoroCheck II ppm Oil in Water benchtop fluorescence
2114-OWM % Water in Oil probe capacitance
9830-HCF Oil on Water Alarm floating sensor capacitance
2114/2214-HCF Oil on Water Monitor   . floating sensor capacitance
9820/9830-OWS Oil Water Separator probe capacitance
2114-OWS Oil Water Separator probe capacitance

Note: This diagram requires Adobe's Flash Player. If you cannot see the animation, download here the free player.

 

HydroSense 2410
On-line ppm Monitor

HydroSense 2410 On-line ppm Monitor

The HydroSense 2410 continuously monitors the water sample flowing through it for ppm concentrations of hydrocarbons. The display, signal output, and alarm can be configured within the 0-1000 ppm range. 

          
    

 HydroSense 2410
 On-Line ppm Monitor
Pages Size File Format

Product Documents

   
Brochure  4 420K  PDF
Operation Manual  - -  PDF
System Overview Drawing  1  44K  PDF
Electrical Drawing  1  95K  PDF
Sample Specification Data Sheet  1  11K  PDF
Sample Written Specification   1  7K  PDF
HydroSense Application Form  1  8K  PDF 
HydroSense part numbers with description  3  11K  PDF

Video Mini-Clips

. . .
NEW! Theory of Operation - -  Video
NEW! Features and Operation - -  Video
NEW! Calibration and Maintenance - -  Video

Related Papers from our library

     
Approvals and Certifications  -  - Webpage
Pumps, Filters and Coolers Review   5  12K  PDF
Interferent and Accuracy Review   3  9K  PDF
Hazardous Location Use Review  2  9K  PDF 
Understanding and Monitoring Hydrocarbons  4  27K  PDF
Overview of Fluorescence and On-Line Monitoring      PDF

 

TOP

 

HydroSense 3410
On-line ppm Monitor

HydroSense 3410 On-line ppm Monitor

The HydroSense 3410 continuously monitors a clean water sample for petroleum hydrocarbon concentrations. The display, signal output, and alarm can be configured within the 0-100 ppm range.

            

 HydroSense 3410
 On-Line ppm Monitor
Pages Size File Format

Product Documents

   
Brochure  2 226K  PDF
Operation Manual  - -  PDF
System Overview Drawing  - -  PDF
Electrical Drawing  - -  PDF
Sample Specification Data Sheet  - -  PDF
Sample Written Specification   - -  PDF
HydroSense Application Form  - -  PDF 
HydroSense part numbers with description  - -  PDF

Video Mini-Clips

NEW! Theory of Operation  -

-

 Video

Related Papers from our library

     
Approvals and Certifications  -  - Webpage
Pumps, Filters and Coolers Review   5  12K  PDF
Interferent and Accuracy Review   3  9K  PDF
Hazardous Location Use Review  2  9K  PDF 
Understanding and Monitoring Hydrocarbons  4  27K  PDF
Overview of Fluorescence and On-Line Monitoring      PDF

TOP

HydroSense 3420
On-line Oil Alarm

HydroSense 3420 On-line ppm Monitor

The HydroSense 3420 continuously monitors a clean water sample for oil leaks. The display, signal output, and alarm can be configured within the 0-100 ppm range.

          

 HydroSense 3420
 On-Line Oil Alarm
Pages Size File Format

Product Documents

   
Brochure  2 103K  PDF
Operation Manual  - -  PDF
System Overview Drawing  - -  PDF
Electrical Drawing  - -  PDF
Sample Specification Data Sheet  - -  PDF
Sample Written Specification   - -  PDF
HydroSense Application Form  - -  PDF 
HydroSense part numbers with description  - -  PDF

Video Mini-Clips

. . .
NEW! Theory of Operation  -

-

 Video

Related Papers from our library

     
Approvals and Certifications  -  - Webpage
Pumps, Filters and Coolers Review   5  12K  PDF
Interferent and Accuracy Review   3  9K  PDF
Hazardous Location Use Review  2  9K  PDF 
Understanding and Monitoring Hydrocarbons  4  27K  PDF
Overview of Fluorescence and On-Line Monitoring      PDF

TOP

 

FluoroCheck II
Benchtop ppm Monitor
 

FluoroCheck II

The FluoroCheck II is benchtop and transportable unit for discrete sample measurements of ppm hydrocarbons in water. Direct water samples for screening or an EPA approved hexane oil extraction method may be used.

            

 FluoroCheck II
 Benchtop ppm Monitor
Pages Size File Format

Product Documents

     
Brochure 2  176K  PDF
Operation Manual  - -  PDF

Video Mini-Clips

     
NEW! Product Overview and Features  -

-

 Video

Related Papers from our library

     
Understanding and Monitoring Hydrocarbons 4 27 k  PDF
Overview of Fluorescence and Benchtop Monitoring      
Approvals and Certifications  -  - Webpage

 

TOP

 

2114-OWM
 % water in oil

2114-OWM % oil in water

The 2114-OWM is used for monitoring as the water phase changes to oil in a tank or pipe. A probe inserted into a tank or pipe measures the capacitance field. This is ideal for general monitoring of oils and other liquid phase changes in a process.

              

 2114-OWM  % Water in Oil Pages Size File Format

Product Documents

     
Brochure  2  103K  PDF
Operation Manual  - -  PDF
Sample written specification  1  6K  PDF
Dimensional/Electrical Drawing  1  80K  PDF
Part numbers with description  22  87K  PDF

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage

 

TOP

 

9830-HCF
Oil on Water Alarm

9830-HCF Oil on Water Alarm

For separated Oil-on-Water applications, Arjay offers the Hydrocarbon Float Sensor. This floating sensor monitors the surface of water in sumps, tanks, and lagoons to alert when oil has separated to the water surface. This is typically used to alert of spills or control pumps.

          

 9830-HCF Floating Oil Sensor Pages Size File Format

Product Documents

     
Brochure  2  256K  PDF
Operation Manual  - -  PDF
Sample written specification  1  6K  PDF
Dimensional/Electrical Drawing  1  80K  PDF
Part numbers with description  22  87K  PDF

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage

9830-HCF Oil on Water Alarm

TOP

 

2114-HCF / 2214-HCF
Floating Oil Thickness Monitor

2114-HCF / 2214-HCF Oil Thickness Monitor

The 2114/2214 monitors a floating sensor on the water surface to indicate the thickness of separated oil. An LCD display of the thickness, analog output and relay alarms are standard.

            

 2114-HCF/2214-HCF
 Floating Oil Thikness Monitor
Pages Size File Format

Product Documents

     
Brochure  2  246K  PDF
Operation Manual  - -  PDF
Sample written specification  1  8K  PDF
Sample Specification Data Sheet      PDF
Dimensional and Electrical Drawing for 2" oil range sensor  1  85K  PDF
Dimensional and Electrical Drawing for 24" oil range sensor  1  86K   PDF
Part numbers with description  22  87K  PDF

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage

2114-HCF / 2214-HCF Oil Thickness Monitor

TOP

9820/9830-OWS / 2114-OWS
Oil Water Separator

9820/9830-OWS / 2114-OWS Oil Water Separator
2114-OWS

Contained oil/water separators, sumps and pumps can be monitored using a point switch alarm (9820/9830) set for a determined interface level. If an indication of the actual interface level is desired, Arjay offers a continuous interface monitor (2114).

             

9820/9830-OWS / 2114-OWS Oil Water Separator

 9820-OWS
 Oil/Water Separator Level Alarm
Pages Size File Format

Product Documents

     
Brochure  2  186K  PDF
Operation Manual  - -  PDF
Sample written specification  1  7K  PDF
Sample Specification Data Sheet      
l drawing  1  37K  PDF
Part numbers with description      

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage
 
 9830-OWS
 Oil/Water Separator Level Alarm
Pages Size File Format

Product Documents

     
Brochure  2  186K  PDF
Operation Manual  - -  PDF
Sample written specification  1  7K  PDF
Sample Specification Data Sheet      
9830-OWS dimensional and electrical drawing  1  69K  PDF
Part numbers with description  22  87K  PDF

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage
 
 2114-OWS
 Oil/Water Separator Monitor
Pages Size File Format

Product Documents

     
Brochure  2  204K  PDF
Operation Manual  - -  PDF
Overview Drawing  1  44K  PDF
Dimensional and Electrical Drawing  1   87K  PDF
Sample written specification  1  7K  PDF
Sample Specification Data Sheet      
Part numbers with description  22  87K  PDF

Related Papers from our library

     
What is Capacitance ?  5  15K  PDF
Approvals and Certifications  -  - Webpage


Level Monitors | Oil in Water Monitors | Liquid Spill and Leak Alarms | Interstitial Tank Leak Alarms | Dry Run Monitors | Plugged Chute Detectors | Open Channel Flow Monitors | Gas Detection

Home | News | Company Information | Document Library | Reps | Info Request | Manuals | Certifications | SiteMap


Copyright © 1996-2009, ARJAY ENGINEERING Ltd.
2851 Brighton Rd., Oakville, Ontario, Canada L6H 6C9  (Street Map)
Tel:(905) 829-2418 or toll free 1-800-387-9487 (North America only)
Fax:(905)-829-4701
e-mail: arjay@arjayeng.com

Designed by   Webstar Solutions